Basit öğe kaydını göster

dc.contributor.authorÖzkan, Haydar
dc.date.accessioned2021-06-15T10:55:56Z
dc.date.available2021-06-15T10:55:56Z
dc.date.issued2017en_US
dc.identifier.citationÖZKAN, Haydar. "Rapid Daignostic Lateral Flow Strip Test Reader". Balkan Journal of Electrical & Computer Engineering, 5.2 (2017): 34-39.en_US
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/334554
dc.identifier.urihttps://hdl.handle.net/11352/3626
dc.description.abstractNon-invasive rapid diagnostic tests (RDT) are commonly used to detect some kind of viruses or bacteria instead of invasive methods. Helicobacter pylori (H. Pylori) which causes gastric cancer, peptic ulcer, gastritis, mucosa-associated lymphoid tissue lymphoma diseases can be detected easily with lateral flow strip (LFS) that is one of the RDT types. The tests are evaluated whether there are control line and test line at the region of interest (ROI) by users or microbiology technicians manually. Once the test line is tentative, despite the test must be reported positive, it can be resulted as negative incorrectly. This incorrect diagnose causes incorrect treatment planning. In this work, to mitigate this problem which will be able to occur by human based, an automatic LFS-RDT reading system is developed. The computer laptop based system firstly takes image utilizing the holders that are designed with 3D printer. Whether the test have the control-test lines or not are carried out by image processing techniques straightforwardly. After feature extraction from line areas, k-NN classification method is used to evaluate the test results automatically. 100 LFS-RDTs are tested and observed that all results are correct. The system is found quite useful and approved as a second reader by medical technicians.en_US
dc.language.isoengen_US
dc.publisherBalkan Yayınen_US
dc.relation.isversionof10.17694/bajece.334337en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRapid Diagnostic Test Readeren_US
dc.subjectClassificationen_US
dc.subjectk-NNen_US
dc.subjectImage Processingen_US
dc.titleRapid Daignostic Lateral Flow Strip Test Readeren_US
dc.typearticleen_US
dc.relation.journalBalkan Journal of Electrical & Computer Engineeringen_US
dc.contributor.departmentFSM Vakıf Üniversitesi, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümüen_US
dc.identifier.volume5en_US
dc.identifier.issue2en_US
dc.identifier.startpage34en_US
dc.identifier.endpage39en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.institutionauthorÖzkan, Haydar


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster