In Situ Dynamic System Identification of Historic Masonry Monuments Based on Non-destructiveTesting

Thumbnail

Göster/Aç

Ana makale (3.529Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2021

Yazar

Dabanlı, Ömer
Kahya, Yegan
Çılı, Feridun

Üst veri

Tüm öğe kaydını göster

Künye

DABANLI, Ömer, Yegan KAHYA & Feridun ÇILI. "In Situ Dynamic System Identification of Historic Masonry Monuments Based on Non-destructiveTesting". A/Z ITU Journal of the Faculty of Architecture, 18:3 (2021): 637-651.

Özet

Istanbul is home to numerous architectural heritage which are in a great variety built by Byzantine and Ottoman period. On the other hand, cultural heritage buildings are faced with serious earthquake risks which require the investigation of the structural behaviour of cultural heritage buildings and the taking of necessary conservation measures to preserve and transfer them to the future in a sustainable way. This article describes an experimental in-situ investigation of an 18th century historic masonry monument, Nur-u Osmaniye Mosque in Istanbul by the non-destructive testing. Dynamic system identification study based on operational modal analysis (OMA) tests which include two different test setups in terms of locations and numbers of accelerometers. The extracted dynamic parameters of structure such as natural frequencies, mode shapes and as well as damping ratios obtained from two different test setups compared. In addition, the results of non-destructive in-situ tests used for the 3D Finite Element (FE) model updating by comparing and calibrating numerical and experimental characteristics. The paper presents an in situ dynamic identification procedure of an historic masonry monument based on operational modal analysis and compares dynamic properties obtained from experimental and numerical studies and gives the results of FE model updating of the structure.

Kaynak

A/Z ITU Journal of the Faculty of Architecture

Cilt

18

Sayı

3

Bağlantı

https://jag.journalagent.com/itujfa/pdfs/ITUJFA_18_3_637_651.pdf
https://hdl.handle.net/11352/4002

Koleksiyonlar

  • Mimarlık Bölümü [140]
  • Scopus İndeksli Yayınlar / Scopus Indexed Publications [630]
  • TR-Dizin İndeksli Yayınlar / TR-Dizin Indexed Publications [587]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@FSM

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber || Kütüphane || FSM Vakıf Üniversitesi || OAI-PMH ||

FSM Vakıf Üniversitesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
FSM Vakıf Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@FSM:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.