| dc.contributor.author | Tavukçuoğlu, Özlem | |
| dc.contributor.author | Erçi, Vildan | |
| dc.contributor.author | Çiftçi, Fatih | |
| dc.contributor.author | Işıldak, İbrahim | |
| dc.contributor.author | Kasapoğlu, Muhammed Zahid | |
| dc.date.accessioned | 2025-04-07T14:39:04Z | |
| dc.date.available | 2025-04-07T14:39:04Z | |
| dc.date.issued | 2025 | en_US |
| dc.identifier.citation | TAVUKÇUOĞLU, Özlem, Vildan ERÇİ, Fatih ÇİFTÇİ, İbrahim IŞILDAK & Muhammed Zahid KASAPOĞLU. "A New Monohydrogen Phosphate-Selective Carbon Composite Membrane Electrode for Soil Water Samples". C : Journal of Carbon Research, 11.18 (2025): 1-16. | en_US |
| dc.identifier.uri | https://www.mdpi.com/2311-5629/11/1/18 | |
| dc.identifier.uri | https://hdl.handle.net/11352/5273 | |
| dc.description.abstract | This study focused on developing a novel composite phosphate-selective electrode
for on-site and real-time applications using a silver polyglutaraldehyde phosphate
and carbon nanotube (CNT) matrix. CNT-silver polyglutaraldehyde phosphate compound
was synthesized and characterized using Fourier-transform infrared spectroscopy (FTIR),
scanning electron microscopy (SEM), X-ray diffraction (XRD), and thermogravimetric analysis
(TGA). The potentiometric performance of the composite phosphate-selective electrode
was then investigated. The results demonstrated that the composite phosphate-selective
electrode exhibited good sensitivity, with a linear response in the concentration range of
1.0 × 10−4 to 1.0 × 10−2 M for phosphate ions. The electrode also showed high selectivity
towards phosphate ions compared to other anions, such as chloride and nitrate. Additionally,
the electrode displayed a quick response time of less than 15 s, making it suitable for
real-time measurements. The electrode was applied to surface and soil water samples. The
results obtained from the water samples showed a strong correlation with those obtained
from the preferred spectrophotometry method, highlighting the potential of the developed
electrode for on-site and continuous monitoring of phosphate and offering an efficient and
practical solution for various fields that require phosphate detection. | en_US |
| dc.language.iso | eng | en_US |
| dc.publisher | MDPI | en_US |
| dc.relation.isversionof | 10.3390/c11010018 | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Composite Matrix | en_US |
| dc.subject | Phosphate-selective Electrode | en_US |
| dc.subject | Solid Contact | en_US |
| dc.subject | Soil Analysis | en_US |
| dc.title | A New Monohydrogen Phosphate-Selective Carbon Composite Membrane Electrode for Soil Water Samples | en_US |
| dc.type | article | en_US |
| dc.relation.journal | C : Journal of Carbon Research | en_US |
| dc.contributor.department | FSM Vakıf Üniversitesi, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümü | en_US |
| dc.contributor.authorID | https://orcid.org/0000-0001-9584-676X | en_US |
| dc.contributor.authorID | https://orcid.org/0000-0002-3062-2404 | en_US |
| dc.contributor.authorID | https://orcid.org/0000-0001-9654-1386 | en_US |
| dc.identifier.volume | 11 | en_US |
| dc.identifier.issue | 18 | en_US |
| dc.identifier.startpage | 1 | en_US |
| dc.identifier.endpage | 16 | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.contributor.institutionauthor | Çiftçi, Fatih | |