• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@FSM Vakıf
  • Fakülteler / Faculties
  • Sanat, Tasarım ve Mimarlık Fakültesi / Faculty of Arts, Design and Architecture
  • Mimarlık Bölümü
  • Öğe Göster
  •   DSpace@FSM Vakıf
  • Fakülteler / Faculties
  • Sanat, Tasarım ve Mimarlık Fakültesi / Faculty of Arts, Design and Architecture
  • Mimarlık Bölümü
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Structural Evaluation of Masonry Walls with Double-sided CFRP Reinforcement Through Ddiagonal Compression Tests

Thumbnail

Göster/Aç

Ana Makale (13.39Mb)

Erişim

info:eu-repo/semantics/embargoedAccess

Tarih

2025

Yazar

Torunbalcı, Necdet
Onar, Ertan
Günay, Hilal

Üst veri

Tüm öğe kaydını göster

Künye

TORUNBALCI, Necdet, Ertan ONAR & Hilal GÜNAY. "Structural Evaluation of Masonry Walls with Double-sided CFRP Reinforcement Through Ddiagonal Compression Tests". Journal of Building Engineering, 111 (2025): 1-22.

Özet

Possible damages in masonry structures due to aging, settlement, movement, or earthquake effects can be repaired/reinforced with minimum intervention. In this study, the effect of CFRP composites, which can be applied in this sense, on structural strengthening was investigated with experiments performed on 3 different series. In the study, firstly, model brick wall specimens were produced with bricks cut from standard bricks (19x9x5 cm) in miniature brick sizes (9.5x4.5 × 2.5 cm) and these specimens exposed to loading and damaged. Thus, the characteristics of the reference wall were determined. Following the initial damage, the cracks in the specimens were repaired using epoxy. Subsequently, three different CFRP configurations -strip, split strip, and fabric-were applied to both sides of the wall specimens, which were divided into three groups. After reinforcement, the testing phase was initiated. To simulate possible horizontal and vertical loads, a diagonal compressive force was applied to the specimens with the horizontal joints at an 45◦ angle to the load axis. The strengths, deformations, and failure mechanisms of the model masonry walls subjected to diagonal compressive loading were recorded, and the effect of CFRP reinforcement on masonry walls under compressive and tensile loads was investigated using experimental data. Compared to the reference walls, an increase in strength by 180–327 %, displacement capacity by 229–359 %, and shear strength by 186–306 % was observed in the CFRP-strengthened specimens.

Kaynak

Journal of Building Engineering

Cilt

111

Bağlantı

https://hdl.handle.net/11352/5341

Koleksiyonlar

  • Mimarlık Bölümü [150]
  • WOS İndeksli Yayınlar / WOS Indexed Publications [609]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@FSM

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber || Kütüphane || FSM Vakıf Üniversitesi || OAI-PMH ||

FSM Vakıf Üniversitesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
FSM Vakıf Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@FSM:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.