• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   FSM Vakıf
  • Fakülteler / Faculties
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği Bölümü
  • View Item
  •   FSM Vakıf
  • Fakülteler / Faculties
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği Bölümü
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effect of Time Step Interval and Time Integration Schemes in Pseudo-Dynamic Analysis

Thumbnail

View/Open

Ana makale (1.075Mb)

Access

info:eu-repo/semantics/embargoedAccess

Date

2023

Author

Öztürk, Sezer
Doran, Bilge
Aksoylar, Cenk

Metadata

Show full item record

Citation

ÖZTÜRK, Sezer, Bilge DORAN & Cenk AKSOYLAR. "Effect of Time Step Interval and Time Integration Schemes in Pseudo-Dynamic Analysis". Structures, (2023): 215-230.

Abstract

Pseudo Dynamic Analysis technique is an alternative method for exploring structural performance by combining analytical and experimental investigation. Compared to shake table tests, it is a more economical method, and its reliability has been proven over many years of the studies. The damage occurrence and process can be monitored on the test sample due to experiments performed at low speeds. In this study, the behaviour of a single degree of freedom, cantilever column system, under the effect of the pulse load and earthquake record was investigated both numerically and experimentally using Pseudo Dynamic Analysis method. The effects of two different time integration schemes and various time step interval values on analyses were examined in the investigations and the results were compared. Numerical analyses were performed by α-operator splitting method and central differences method, and experimental studies were performed by α-operator splitting method. In experimental investigations, approximate results were obtained with numerical studies for certain values of the time step. At small time interval values, experimental results deteriorated. It is purposed to determine the optimum time step interval value that can be utilised in the Pseudo Dynamic Test method.

Source

Structures

Volume

50

URI

https://hdl.handle.net/11352/4320

Collections

  • İnşaat Mühendisliği Bölümü [123]
  • Scopus İndeksli Yayınlar / Scopus Indexed Publications [630]
  • WOS İndeksli Yayınlar / WOS Indexed Publications [568]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@FSM

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Guide || Library || FSM Vakıf University || OAI-PMH ||

FSM Vakıf University, İstanbul, Turkey
If you find any errors in content, please contact:

Creative Commons License
FSM Vakıf University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@FSM:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.