• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@FSM Vakıf
  • Fakülteler / Faculties
  • Mühendislik Fakültesi / Faculty of Engineering
  • Elektrik-Elektronik Mühendisliği Bölümü
  • Öğe Göster
  •   DSpace@FSM Vakıf
  • Fakülteler / Faculties
  • Mühendislik Fakültesi / Faculty of Engineering
  • Elektrik-Elektronik Mühendisliği Bölümü
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

A Low-Cost Microwave Hybrid Biosensor for Glucose Concentration Sensing

Thumbnail

Göster/Aç

Konferans Ögesi (589.7Kb)

Erişim

info:eu-repo/semantics/embargoedAccess

Tarih

2024

Yazar

Köse, Umut
Kartal, Mesut

Üst veri

Tüm öğe kaydını göster

Künye

KÖSE, Umut & Mesut KARTAL. "A Low-Cost Microwave Hybrid Biosensor for Glucose Concentration Sensing". 2024 International Conference on Applied and Theoretical Electricity (ICATE), (2024): 1-5.

Özet

This study uses a hybrid biosensor consisting of a patch antenna with a defected ground plane and a frequencyselective surface (FSS) to detect glucose concentration in the microwave frequency region. The sensing mechanism is based on identifying the relative permittivity and loss tangent variations caused by different ratios of glucose-distilled water solutions placed in the area of the sample under test (SUT). This study tested four glucose-distilled water solutions in the SUT region: 72 mg/dL, 216 mg/dL, 330 mg/dL, and 600 mg/dL. The Debye model is utilized to ascertain the dielectric characteristics of the solutions. When the volume percentage of glucose in the glucose-deionized water solutions in the SUT increased from 72 mg/dL to 600 mg/dL, a frequency shift of 44 MHz was observed in the resonance frequency of the hybrid sensor called Sensor 1. To show the effect of mutual coupling between the defected ground plane and the FSS on sensitivity parameters in the hybrid sensor structure, a new sensor called Sensor 2 was designed. Sensor 2 has the same geometry and dimensional parameters as Sensor 1 but only consists of a patch antenna with a defected ground plane. A frequency shift of 7 MHz was noted in the resonance frequency of Sensor 2 when the volume percentage of glucose in the glucose-deionized water solutions in the SUT increased from 72 mg/dL to 600 mg/dL. According to the simulation results, the sensitivity of Sensor 1 was calculated as 83.333 kHz/mg dL-1, while Sensor 2 was 13.258 kHz/mg dL-1. Thus, it is shown that FSS can be used in antenna-based sensor structures for sensitivity improvement.

Kaynak

2024 International Conference on Applied and Theoretical Electricity (ICATE)

Bağlantı

https://hdl.handle.net/11352/5126

Koleksiyonlar

  • Elektrik-Elektronik Mühendisliği Bölümü [75]
  • Scopus İndeksli Yayınlar / Scopus Indexed Publications [756]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@FSM

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber || Kütüphane || FSM Vakıf Üniversitesi || OAI-PMH ||

FSM Vakıf Üniversitesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
FSM Vakıf Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@FSM:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.