dc.contributor.author | Tan, Remziye İlayda | |
dc.contributor.author | Arslankaya, Ertan | |
dc.contributor.author | Kesgin, Erdal | |
dc.contributor.author | Ağaçcıoğlu, Hayrullah | |
dc.date.accessioned | 2021-08-12T12:08:05Z | |
dc.date.available | 2021-08-12T12:08:05Z | |
dc.date.issued | 2021 | en_US |
dc.identifier.citation | TAN, Remziye İlayda, Ertan ARSLANKAYA, Erdal KESGİN & Hayrullah AĞAÇCIOĞLU. "Determination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkey". Water Environment Federation, (2021): 1-14. | en_US |
dc.identifier.uri | https://hdl.handle.net/11352/3798 | |
dc.description.abstract | The design of wastewater system pipe size is traditionally based on the maximum
wastewater flow that is a function of multiple factors. Understanding the
appropriate peaking factors (PF) by using daily flow variations through wastewater
collection systems (WWCS) is essential for cost-effective design. This
paper describes the maximum and minimum PFs by using wastewater flow
data of four separate residential areas such as Lara, Belek-1, Kemer, and
Hurma in Antalya, which is the tourism capital of Turkey. The study involves
the analysis of wastewater data recorded at daily interval for two different time
periods (2006–2009 and 2016–2019) in Antalya. There is a comprehensive
investigation regarding PFs that involves sustained peaking flow and percentiles.
Therefore, a new empirical equation was proposed by using wastewater
flowrate for the estimation of the maximum daily peaking factor. When the
daily PFs are determined in the range of 1.31–1.52, 1.60–2.58, 2.26–3.29, and
1.93–2.29 for Lara, Belek-1, Kemer, and Hurma wastewater treatment plants
(WWTPs) for 2016–2019 time period, they are in the range of 2.19–2.93 and
1.95–3.31 for Lara and Hurma WWTPs for the time period of 2006–2009,
respectively. In brief, this study presents a comprehensive calculation of PFs
with a determination of their sustained flow analysis with different durations
and percentiles. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Wiley Online Library | en_US |
dc.relation.isversionof | 10.1002/wer.1612 | en_US |
dc.rights | info:eu-repo/semantics/embargoedAccess | en_US |
dc.subject | Flow | en_US |
dc.subject | Peaking Factor | en_US |
dc.subject | Percentile | en_US |
dc.subject | Sustained Flow | en_US |
dc.subject | Wastewater | en_US |
dc.subject | WWTP | en_US |
dc.title | Determination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkey | en_US |
dc.type | article | en_US |
dc.relation.journal | Water Environment Federation | en_US |
dc.contributor.department | FSM Vakıf Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü | en_US |
dc.contributor.authorID | https://orcid.org/0000-0002-9441-5359 | en_US |
dc.identifier.startpage | 1 | en_US |
dc.identifier.endpage | 14 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.institutionauthor | Tan, Remziye İlayda | |