• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@FSM Vakıf
  • Fakülteler / Faculties
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği Bölümü
  • Öğe Göster
  •   DSpace@FSM Vakıf
  • Fakülteler / Faculties
  • Mühendislik Fakültesi / Faculty of Engineering
  • İnşaat Mühendisliği Bölümü
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Determination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkey

Thumbnail

Göster/Aç

Ana Makale (3.274Mb)

Erişim

info:eu-repo/semantics/embargoedAccess

Tarih

2021

Yazar

Tan, Remziye İlayda
Arslankaya, Ertan
Kesgin, Erdal
Ağaçcıoğlu, Hayrullah

Üst veri

Tüm öğe kaydını göster

Künye

TAN, Remziye İlayda, Ertan ARSLANKAYA, Erdal KESGİN & Hayrullah AĞAÇCIOĞLU. "Determination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkey". Water Environment Federation, (2021): 1-14.

Özet

The design of wastewater system pipe size is traditionally based on the maximum wastewater flow that is a function of multiple factors. Understanding the appropriate peaking factors (PF) by using daily flow variations through wastewater collection systems (WWCS) is essential for cost-effective design. This paper describes the maximum and minimum PFs by using wastewater flow data of four separate residential areas such as Lara, Belek-1, Kemer, and Hurma in Antalya, which is the tourism capital of Turkey. The study involves the analysis of wastewater data recorded at daily interval for two different time periods (2006–2009 and 2016–2019) in Antalya. There is a comprehensive investigation regarding PFs that involves sustained peaking flow and percentiles. Therefore, a new empirical equation was proposed by using wastewater flowrate for the estimation of the maximum daily peaking factor. When the daily PFs are determined in the range of 1.31–1.52, 1.60–2.58, 2.26–3.29, and 1.93–2.29 for Lara, Belek-1, Kemer, and Hurma wastewater treatment plants (WWTPs) for 2016–2019 time period, they are in the range of 2.19–2.93 and 1.95–3.31 for Lara and Hurma WWTPs for the time period of 2006–2009, respectively. In brief, this study presents a comprehensive calculation of PFs with a determination of their sustained flow analysis with different durations and percentiles.

Kaynak

Water Environment Federation

Bağlantı

https://hdl.handle.net/11352/3798

Koleksiyonlar

  • İnşaat Mühendisliği Bölümü [136]
  • Scopus İndeksli Yayınlar / Scopus Indexed Publications [756]
  • WOS İndeksli Yayınlar / WOS Indexed Publications [661]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@FSM

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Rehber || Kütüphane || FSM Vakıf Üniversitesi || OAI-PMH ||

FSM Vakıf Üniversitesi, İstanbul, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
FSM Vakıf Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@FSM:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.