Determination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkey

dc.contributor.authorTan, Remziye İlayda
dc.contributor.authorArslankaya, Ertan
dc.contributor.authorKesgin, Erdal
dc.contributor.authorAğaçcıoğlu, Hayrullah
dc.date.accessioned2021-08-12T12:08:05Z
dc.date.available2021-08-12T12:08:05Z
dc.date.issued2021en_US
dc.departmentFSM Vakıf Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.description.abstractThe design of wastewater system pipe size is traditionally based on the maximum wastewater flow that is a function of multiple factors. Understanding the appropriate peaking factors (PF) by using daily flow variations through wastewater collection systems (WWCS) is essential for cost-effective design. This paper describes the maximum and minimum PFs by using wastewater flow data of four separate residential areas such as Lara, Belek-1, Kemer, and Hurma in Antalya, which is the tourism capital of Turkey. The study involves the analysis of wastewater data recorded at daily interval for two different time periods (2006–2009 and 2016–2019) in Antalya. There is a comprehensive investigation regarding PFs that involves sustained peaking flow and percentiles. Therefore, a new empirical equation was proposed by using wastewater flowrate for the estimation of the maximum daily peaking factor. When the daily PFs are determined in the range of 1.31–1.52, 1.60–2.58, 2.26–3.29, and 1.93–2.29 for Lara, Belek-1, Kemer, and Hurma wastewater treatment plants (WWTPs) for 2016–2019 time period, they are in the range of 2.19–2.93 and 1.95–3.31 for Lara and Hurma WWTPs for the time period of 2006–2009, respectively. In brief, this study presents a comprehensive calculation of PFs with a determination of their sustained flow analysis with different durations and percentiles.en_US
dc.identifier.citationTAN, Remziye İlayda, Ertan ARSLANKAYA, Erdal KESGİN & Hayrullah AĞAÇCIOĞLU. "Determination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkey". Water Environment Federation, (2021): 1-14.en_US
dc.identifier.doi10.1002/wer.1612
dc.identifier.endpage14en_US
dc.identifier.issn1061-4303
dc.identifier.issn1554-7531
dc.identifier.orcidhttps://orcid.org/0000-0002-9441-5359en_US
dc.identifier.pmid34273204
dc.identifier.scopus2-s2.0-85111481764
dc.identifier.scopusqualityQ1
dc.identifier.startpage1en_US
dc.identifier.urihttps://hdl.handle.net/11352/3798
dc.identifier.wosWOS:000678674900001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorTan, Remziye İlayda
dc.language.isoen
dc.publisherWiley Online Libraryen_US
dc.relation.ispartofWater Environment Federation
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectFlowen_US
dc.subjectPeaking Factoren_US
dc.subjectPercentileen_US
dc.subjectSustained Flowen_US
dc.subjectWastewateren_US
dc.subjectWWTPen_US
dc.titleDetermination of Peaking Factors for Sewerage System in Antalya, Tourism Capital of Turkeyen_US
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tan.pdf
Boyut:
3.27 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Ana Makale

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: