Structural Evaluation of Masonry Walls with Double-sided CFRP Reinforcement Through Ddiagonal Compression Tests

dc.contributor.authorTorunbalcı, Necdet
dc.contributor.authorOnar, Ertan
dc.contributor.authorGünay, Hilal
dc.date.accessioned2025-06-30T12:46:44Z
dc.date.available2025-06-30T12:46:44Z
dc.date.issued2025en_US
dc.departmentFSM Vakıf Üniversitesi, Mimarlık ve Tasarım Fakültesi, Mimarlık Bölümüen_US
dc.description.abstractPossible damages in masonry structures due to aging, settlement, movement, or earthquake effects can be repaired/reinforced with minimum intervention. In this study, the effect of CFRP composites, which can be applied in this sense, on structural strengthening was investigated with experiments performed on 3 different series. In the study, firstly, model brick wall specimens were produced with bricks cut from standard bricks (19x9x5 cm) in miniature brick sizes (9.5x4.5 × 2.5 cm) and these specimens exposed to loading and damaged. Thus, the characteristics of the reference wall were determined. Following the initial damage, the cracks in the specimens were repaired using epoxy. Subsequently, three different CFRP configurations -strip, split strip, and fabric-were applied to both sides of the wall specimens, which were divided into three groups. After reinforcement, the testing phase was initiated. To simulate possible horizontal and vertical loads, a diagonal compressive force was applied to the specimens with the horizontal joints at an 45◦ angle to the load axis. The strengths, deformations, and failure mechanisms of the model masonry walls subjected to diagonal compressive loading were recorded, and the effect of CFRP reinforcement on masonry walls under compressive and tensile loads was investigated using experimental data. Compared to the reference walls, an increase in strength by 180–327 %, displacement capacity by 229–359 %, and shear strength by 186–306 % was observed in the CFRP-strengthened specimens.en_US
dc.identifier.citationTORUNBALCI, Necdet, Ertan ONAR & Hilal GÜNAY. "Structural Evaluation of Masonry Walls with Double-sided CFRP Reinforcement Through Ddiagonal Compression Tests". Journal of Building Engineering, 111 (2025): 1-22.en_US
dc.identifier.doi10.1016/j.jobe.2025.113142
dc.identifier.endpage22en_US
dc.identifier.issn2352-7102
dc.identifier.scopus2-s2.0-105007982880
dc.identifier.scopusqualityQ1
dc.identifier.startpage1en_US
dc.identifier.urihttps://hdl.handle.net/11352/5341
dc.identifier.volume111en_US
dc.identifier.wosWOS:001512927600001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorGünay, Hilal
dc.language.isoen
dc.publisherElsevieren_US
dc.relation.ispartofJournal of Building Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectMasonry wallen_US
dc.subjectCFRP strengtheningen_US
dc.subjectDiagonal compression testen_US
dc.subjectSeismic retrofiten_US
dc.subjectExperimental studyen_US
dc.titleStructural Evaluation of Masonry Walls with Double-sided CFRP Reinforcement Through Ddiagonal Compression Testsen_US
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Torunbalcı.pdf
Boyut:
13.4 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Ana Makale

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: