Deep Learning–Assisted Malaria Microscopy with Sensitivity-Aware Threshold Optimization

dc.contributor.authorDehbi, Fatma
dc.contributor.authorHamou, Reda Mohamed
dc.contributor.authorBrahami, Menaouer
dc.contributor.authorShaaban, Sahmoud
dc.contributor.authorGhoul, Abdelhamid
dc.contributor.authorLatreche, Ameur
dc.contributor.authorDjeffal, Selman
dc.date.accessioned2026-09-29T11:03:51Z
dc.date.issued2026
dc.departmentFSM Vakıf Üniversitesi, Rektörlük, Yapay Zekâ ve Veri Bilimi Uygulama ve Araştırma Merkezi
dc.description.abstractMalaria microscopy becomes clinically risky when parasitized erythrocytes are missed, even when a classifier reports high overall accuracy. This study presents an artificial-intelligence-assisted malaria microscopy framework that explicitly optimizes the diagnostic operating point for sensitivity-aware screening. A balanced set of 27,558 National Institutes of Health/National Library of Medicine (NIH/NLM) thin-smear cell images was divided by stratified image-level sampling in the ratio 70:15:15 for training, validation, and independent testing. Two custom convolutional neural networks (CNNs) with complementary capacity–regularization profiles and an equal-weight score-level ensemble were evaluated. Training-only online augmentation, fixed input resizing, validation-only threshold selection, confidence intervals, and error analysis were incorporated to improve reproducibility. At the conventional threshold, the compact CNN achieved the highest accuracy (95.26%). After optimizing the operating point with the recall-weighted F2 objective, the deeper CNN provided the strongest screening-oriented result on the held-out test set, reaching 97.05% sensitivity (95% confidence interval: 96.23%–97.70%), a 96.01% F2-score, a 2.95% false-negative rate, and a receiver-operating-characteristic area under the curve of 0.9876 (95% confidence interval: 0.9842–0.9910). It reduced missed parasitized cells from 177 to 61 relative to its default threshold. The public release does not provide patient identifiers; therefore, the reported split is image-level rather than confirmed to be patient-level independent, and external multicenter validation remains necessary before clinical deployment. The main finding is that the highest-accuracy classifier is not necessarily the most appropriate sensitivity-oriented screening configuration.
dc.identifier.citationDEHBİ, Fatma, Reda Mohamed HAMOU, Menaouer BRAHAMI, Sahmoud SHAABAN, Abdelhamid GHOUL, Ameur LATRECHE & Selman DJEFFAL. "Deep Learning–Assisted Malaria Microscopy with Sensitivity-Aware Threshold Optimization". Frontiers in Medicine, 13 (2026): 1-19.
dc.identifier.doi10.3389/fmed.2026.1911275
dc.identifier.endpage19
dc.identifier.startpage1
dc.identifier.urihttps://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2026.1911275/full
dc.identifier.urihttps://hdl.handle.net/11352/6311
dc.identifier.volume13
dc.identifier.wosWOS:001869766600001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherFrontiers
dc.relation.ispartofFrontiers in Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectConvolutional Neural Networks
dc.subjectDeep Learning
dc.subjectExplainable Artificial Intelligence
dc.subjectMalaria Detection
dc.subjectMedical Image Classification
dc.subjectMicroscopy Image Analysis
dc.subjectSensitivity Optimization
dc.titleDeep Learning–Assisted Malaria Microscopy with Sensitivity-Aware Threshold Optimization
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Dehbi.pdf
Boyut:
4.44 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: